cneke
 home<<product information<<detailed information
SGB11 H class insulation amorphous alloy transformer
SGB11 H class insulation amorphous alloy transformer
This series is the new type products that produced based on the SG10 H class insulation open ventilation dry-type transformer and the advanced technology of America. It has good performance and therefore greatly reduces the no-load loss, and the load-loss. It is the most advanced transformer at the present. It has the features of safety, reliable, energy-saving and can go deep into the load center. It is especially suitable for the development of the modern society.
  • functional
  • use condition
  • applied range
  • picture
  • certification
  • The core is made of amorphous alloy material and applies the structure of rectangular section and the four-five boxes. The no-load loss is 75% lower than the normal transformer. The low-tension lines applies the copper foil wrapped way and has strong ability of withstanding short-circuit. The high-tension lines applies the NOMEX® insulation system and the continuous structure and impregnated by the H-solvent-free resin and cured after high temperature and therefore has good cooling system and high mechanical property.
    Advantages:
    1. The product applies the NOMEX® insulation system, and therefore has the features of flame-retardant, explosion-proof, non-pollution and has good performance to the fire.
    2. High mechanical property, strong ability of withstanding short-circuit, and running safely.
    3. Low loss, low partial discharge and good effect of energy-saving.
    4. Low noise, small size, easy installation and maintenance-free.
    5. High insulation level and long life of use.
    6. No crack.
    7. It can be recovered after decomposition and non-pollution
    8. Strong overloads ability and can run for a long time with the 120% overload.
  • Use conditions
    1.Altitude
    2.Altitude is no higher than 1000m
    3.environment humidity
    max temperature +40℃
    4.Max daily average temperature +30℃
    5.Max monthly average temperature +20℃
    6.Min temperature -30℃ (applies to outdoor transformers)
    7.Min temperature -5 ℃( applies to indoor transformers)
    8.Wave of Power voltage
    9.It is similar to sin wave
    10.Systematical of the multi-phase power voltage
    11.it is systematical
  • The products have the advantages of flame-retardant, moisture-resistance and no crack and maintenance free, and therefore can be widely used in the places such as skyscraper, shopping center, subway, airport, railway station, industrial and mining enterprise, power plants where the requirements to the fire is high.
  • ...
  • ...